Cyanuric acid (CYA) is chlorine's sunscreen. A little bit protects your chlorine from UV breakdown. Too much and your chlorine becomes too well-protected to actually sanitize.

If your test strip reads CYA above 80 ppm, you have a problem no amount of chemistry can fix.

Why “CYA reducer” products don't work

Walk into any pool store and you'll find bottles of “cyanuric acid reducer.” They're either:

  • Enzyme blends that break down organics — not CYA.
  • Products that maybe lower CYA if used weekly for months, for the cost of a small partial drain.
  • Placebos.

The chemistry is unambiguous: cyanuric acid doesn't break down on its own timescale. It has to be physically removed from the pool.

The real fix: a partial drain

Drain and refill dilutes CYA proportionally. If you drain 25% of your pool and refill with fresh water, CYA drops by roughly 25%.

The formula:

new_CYA = current_CYA × (1 − drain_fraction)

So for CYA at 120 ppm dropping to a target of 50 ppm:

50 = 120 × (1 − drain_fraction)
drain_fraction = 1 − (50 / 120) = 0.58 → drain 58%

Practically: drain to roughly the top of your skimmer opening, refill from the tap, retest.

Do this safely

  • Never drain more than half of a plaster pool at once during hot weather — hydrostatic pressure and thermal shock can crack the shell. Fiberglass pools are more sensitive still.
  • If you're unsure about the shell, drain in stages over multiple days, refilling in between.
  • After refill, expect to re-adjust every other parameter. Fresh municipal water rarely matches pool balance.

How BlueLook handles this

When we detect CYA above 80 ppm, we don't generate a dose report. We show a scope warning telling you a drain is needed and why. Full details on our Science page's scope guardrails section.

Prevention

Trichlor tablets add ~0.6 ppm CYA for every ppm of FC they add. If you rely heavily on trichlor and never partial-drain, CYA creeps up over the season. Two mitigations:

  • Rotate trichlor with liquid chlorine or cal-hypo (neither adds CYA).
  • Plan for a spring partial drain to reset every season.